Microreactor

SKU
Microreactor
Availability:
check_circle In stock
As low as $416.59

per pack of 3

Pack of 3 microreactor chips.

Mixing and heating fluids in a microreactor gives a very high degree of control on the chemical reaction.

The following product options are available:

SKU

Internal volume
(meander)[µl]

Channel width
[µm]

Channel height
[µm]

Inlet channel length
[mm]

Main channel length
[mm]

Manufacturing technique

Thin bottom
[145µm]

Coating

11003694 0.3 50 20 7 328 Etching Yes No
11003644 0.3 50 20 7 328 Etching Yes Hydrophobic
11003040 1.86 140 45 7 343 Etching Yes No
11006834 1.86 140 45 7 343 Etching Yes Hydrophobic
11003033 15.2 250 140 7 494 Etching No No
11006291 15.2 250 140 7 494 Etching No Hydrophobic

Note that chips manufactured using powderblasting have a high channel roughness on the sides and bottom. The top face offers the best optical properties, this is the side with the inlet holes.

More Information
Unit of measurementpack of 3
Interface typeTopconnect
Chip materialBorosilicate glass
Number of inlets2 or 3 (depending on selection)
Number of outlets1
Icon Label Description Type Size Download
pdf Drawing R50.332.3 Serpentine 20x50µm, 342mm pdf 79.1 KB Download
pdf Drawing 11003040 Serpentine 45x140µm, 350mm, TB pdf 76.9 KB Download
pdf Drawing 11003033 Serpentine 140x250µm, 500mm pdf 99.7 KB Download
Customer Questions
How do I clean my uncoated chips?
1) Flush an alkaline solution through the channels, like 1 M sodium hydroxide in water. 2) A water bath with ultrasonic agitation can be used to remove particulated matters, keep energy levels initially low to prevent potential damages. 3) Glass microchips can be heated (e.g. 400°C) causing any organic material on the glass surface to degrade. Try to use lower temperatures first because burning the content could make it stick. 4) Concentrated sulfuric acid works well to dissolve organic material, such as fibres, that are difficult to remove with alkaline solutions.
I have a Elveflow OB1 pressure based pump what connectors do I need?
You need a combination of items supplied by Elveflow and Micronit. Please take a look at the full answer for more details.
I have a Fluigent pressure based pump, what connectors do I need?
See "Read More" for advice.
What's important in selection of a suitable microscope objective?
The objective working distance is a critical parameter for selection of an objective. See "Read More" for recommendations.
What is the roughness of the etched structures?
Wet etched structures are extremely smooth and have a roughness in Angstrom range. The structures are fully optical transparent.
How should I connect the chips to a pump?
Micronit offers a range of chip holders designed to ensure reliable and convenient interfacing between your chip and fluidic tubing. See "Read More"for additional information and links.
Are there alternatives to a chip holder?
While alternatives to a chip holder are available, their implementation is complex and not generally recommended. Further information can be found under “Read More”.
Would you like to submit a question? Please login first.